Mitutoyo HM220B SERIES 200 — Micro Vickers Hardness Testing Machines Code Number 810-408E

Item number:
810-408E
Details
Max. Specimen Height 133mm (stage size 25 x 25mm)
Part Number 810-408E
SPC Output Yes
Resolution .00001mm when using objective of 40x or more
Indenter A maximum of two can be installed 9one indenter shaft with diamond indenter is provided as factory-installed in the main unit)
video
Mitutoyo HM220A SERIES 200 — Micro Vickers Hardness Testing Machines Code Number 810-405E

Mitutoyo HM220A SERIES 200 — Micro Vickers Hardness Testing Machines Code Number 810-405E

Mitutoyo 963-210-20 Series 810 HR-110MR Rockwell  Hardness Tester, Analogue

Mitutoyo 963-210-20 Series 810 HR-110MR Rockwell Hardness Tester, Analogue

Mitutoyo HM220B SERIES 200 — Micro Vickers Hardness Testing Machines Code Number 810-408E

Availability: In stock
Item number
810-408E
Price €29,315.66
Your Saving: €4,593.31
Sale Price €24,722.35 ex vat
Price €29,315.66
Your Saving: €4,593.31
Sale Price €24,722.35 ex vat

 

 

HM-210/220 Series 810- Micro Vickers Hardness Testing Machines

Series 810
FEATURES
  • The latest technology electromagnetic force motor used in the loading mechanism enables the test force to be freely selected (see test force specifications) over the wide range of 0.4903mN to 19610mN (0.05gf to 2 kgf). It is also possible to freely set load dwell times. Now your desire for absolute control over the indentation size in Vickers hardness testing can be satisfied. The HM-200 series always offers the test force most appropriate for the specimen material and shape.
  • The long working distance objectives used enable a very comfortable working distance between the objective and the specimen surface. This, greatly reduces the possibility of collision between the specimen and the objective during focusing operations. (e.g. for 50X objectives: 1.1mm for conventional models, 2.5mm for HM-200 series)
  • Newly-designed ‘MH Plan’ objectives are optimized for measuring indentation images. The lineup includes 6 types of long working distance objectives: 10X, 20X, 50X and 100X for measuring indentation images, and 2X and 5X for enabling wide-range measurement around indentations.
  • LEDs, which have a longer life, produce less heat, consume less power and are more energy efficient than incandescent bulbs, are employed for the illumination system.
  • The motorized turret allows for up to 4 objective lenses and 2 indenter assemblies to be mounted at the same time.

    Technical Data

        Test force range: 

        HM-210A: 9 steps + arbitrary test force

        HM-220A: 19 steps + arbitrary test force

        Load dwell time: 0 - 999s

        Manual XY stage unit

        Stage size: 100x100mm

        Travel range: 25x25mm

        with Digimatic in/mm micrometer heads

        Resolution: 0.001mm

        Max. specimen height: 133mm (Stage size: 25 x 25mm) 

        Max. specimen height: 121mm (Stage size: 50 x 50mm) 

        Max. specimen depth: 160mm (from the center of indenter) 

        Optical path: 4-port objectives switching system of Infinity-correction optical system

        Resolution: 0.01μm (When using objectives of X40 or more) 

        Data output: Serial interface (RS-232), 

        Digimatic interface, USB 2.0

        Power supply: 39VA 100-125/220-240V AC, 50/60Hz

        Dimensions: (W x D x H): 315x671x595mm

        Mass: 43kg



    Optional Accessories
         (Factory-installed option) 

    11AAC104
        : Objective lens unit 2X

    11AAC105
        : Objective lens unit 5X

    11AAC106
        : Objective lens unit 10X

    11AAC107
        : Objective lens unit 20Xv 
    11AAC108
        : Objective lens unit 100X

    11AAC129
        : Measuring microscope (Digital ocular) 

    11AAC109
        : Knoop Indenter Assembly (HM-210 Series) 

    11AAC110
        : Knoop Indenter Assembly (HM-220 Series)



    Optional Accessories
    810-354A
        : TV camera unit (8.4 inch LCD) 

    19BAA058
        : Diamond indenter for Vickers

        (HM210 Series standard test force) 

    19BAA059
        : Diamond indenter for Vickers

        (HM220 Series low test force) 

    19BAA061
        : Diamond indenter for Knoop (HM210 Series) 

    19BAA062
        : Diamond indenter for Knoop (HM220 Series) 

    810-017
        : Vise

    810-013
        : Specimen (thin plate) holder

    810-014
        : Specimen (wire) holder

    810-015
        : Specimen (wire or ball) holder

    810-019
        : Specimen tilting holder

    810-020
        : Universal specimen holder

    810-018
        : Rotary table

    810-084
        : Rotatable universal specimen holder

    810-085
        : Adjustable specimen (thin plate) holder

    810-095
        : Rotatable specimen stage

    375-056
        : Stage Micrometer (glass) Micro-scale

    810-650-1
        : Resin mold specimen stage ø25.4

    810-650-2
        : Resin mold specimen stage ø30

    810-650-3
        : Resin mold specimen stage ø31.75

    810-650-4
        : Resin mold specimen stage ø38.1

    810-650-5
        : Resin mold specimen stage ø40

    02ATE760
        : Table

    810-641
        : Vibration Isolator

    810-870A
        : Sample Heating Device HST-250

    810-420
        : 25x25mm stage (metric only) 

    810-423
        : 50x50mm stage (metric only) 

    810-424
        : 1”x1” in/mm stage (standard) 

    810-427
        : 2”x2” in/mm stage



         
    PC is optional

TYPE A-Digital Hardness Tester
TYPE B-PC Driven Test System
TYPE D-PC Driven Test System with motorized stage and auto focus
 
System D Technical Data 

Motorized X-Y Stage

Travel Max

50 x 50 mm

 

Travel Min

 

Table Size

130 x 130 mm

 

Speed Max

25 mm/ sec

Motorized Focusing Stage

Max Range

1.4 mm

 

Min Unit

.1µ

 

Max Speed

1 mm/ sec

Joystick Controller Functions

Functions

X and Y Lock out

 

Axis

X,Y and Z (Focus)

 

Speed Control

Adjustable H,M,L

 

Tester Control

Indent, Turret Position

 

Other

Emergency Stop

 
 

     

Type A Type B Type D
Model No. HM-210 Type A HM-210 Type A V/K HM-220 Type A HM-220 Type A V/K
Part No. 64AAB305 64AAB306 64AAB307 64AAB308
Image   - - -
Main Unit No. 810-400 810-400 810-405 810-405
Fixed test force (mN) 98.07, 196.1, 294.2, 490.3, 980.7, 1961, 2942,4903, 9807 (10gf-1000gf) 98.07, 196.1, 294.2, 490.3, 980.7, 1961, 2942,4903, 9807 (10gf-1000gf) 0.4903, 0.9807, 1.961, 2.942, 4.903, 9.807, 19.61,29.42, 49.03, 98.07, 196.1, 294.2, 490.3, 980.7,1961, 2942, 4903, 9807, 19610 (0.05 gf-2kgf) 0.4903, 0.9807, 1.961, 2.942, 4.903, 9.807, 19.61,29.42, 49.03, 98.07, 196.1, 294.2, 490.3, 980.7,1961, 2942, 4903, 9807, 19610 (0.05 gf-2kgf)
Arbitrary test force ≤100 gf in 1 gram increments, > 100gf in 10 gram increments ≤100 gf in 1 gram increments, > 100gf in 10 gram increments < 1 gf in .1 gf increments, ≤100 gf in 1 gram increments, > 100gf in 10 gram increments < 1 gf in .1 gf increments, ≤100 gf in 1 gram increments, > 100gf in 10 gram increments
Test force control Force generation by electromagnetic and automatic control (load, dwell, unload) Force generation by electromagnetic and automatic control (load, dwell, unload) Force generation by electromagnetic and automatic control (load, dwell, unload) Force generation by electromagnetic and automatic control (load, dwell, unload)
Control unit Color LCD Touch Screen Color LCD Touch Screen Color LCD Touch Screen Color LCD Touch Screen
Loading Rate 60µ/ sec 60µ/ sec 60µ/ sec 60µ/ sec
Load Dwell Time 0-999 sec 0-999 sec 0-999 sec 0-999 sec
Indenter Vickers Vickers and Knoop Vickers Vickers and Knoop
Objective Lens 10x, 50x 10x, 20x, 50x 10x, 20x, 50x 10x, 20x, 50x
Objective turret Motor driven and manual operation Motor driven and manual operation Motor driven and manual operation Motor driven and manual operation
Filar Eye Piece Dual Line, 10X, .01µ min Dual Line, 10X, .01µ min Dual Line, 10X, .01µ min Dual Line, 10X, .01µ mi
Mitutoyo HM220B SERIES 200 — Micro Vickers Hardness Testing Machines Code Number 810-408E
Price €29,315.66
Your Saving: €4,593.31
Sale Price €24,722.35 ex vat
Product Accessories